EU DPP Platform

Digitaler Produktpass · EVB · item

Voltaris NMC-800 EV pack

Aktiv Version 1 · 09.11.2026, 17:35 UTC

Wirtschaftsakteur: Voltaris Energy GmbH (fictional demo company) · EORI DE123456789012345 · LEI 529900DEMO0VOLTARIS7 · voltaris.example

800 V, 92 kWh lithium-ion NMC traction battery for passenger EVs (fictional demo product).

Eckdaten

Chemie
Li-ion NMC - Lithium ion NMC
Kapazität
230 Ah
Gewicht
452,5 kg
Nennspannung
800 V
Hergestellt
September 2026
Herstellungsort
Leipzig, DEU
Handelsgarantie
96 Monate
Erwartete Lebensdauer
2.500 Zyklen

Dies ist ein Batteriepass nach Verordnung (EU) 2023/1542.

Passdaten

Public

Annex XIII (1)
Identity of who is registering and/or is responsible for the battery passportArticle 77 (3)

Definition: Identity of who is registering and/or is responsible for the battery passport [name]

MOCK-ORG-VOLTARIS
Manufacturer identificationAnnex VI Part A 1

Definition: Manufacturer name, registered trade name or registered trademark [at least one of]

Manufacturer name
Voltaris Energy GmbH
Manufacturer registered trade name
Voltaris
Manufacturer registered trademark
VOLTARIS®
Manufacturer postal addressAnnex VI Part A 1

Definition: Manufacturer single contact postal address

Batteriestraße 1, 10115 Berlin, Germany
Manufacturer contact detailsAnnex VI Part A 1

Definition: If available, manufacturer web and email address [both optional]

Manufacturer email address
passport@voltaris.example
Manufacturer website
https://voltaris.example
Battery categoryAnnex VI Part A 2

Definition: Battery category [3-code list]

EVB - Electric vehicle battery
Battery identificationAnnex VI Part A 2

Definition: Model identification and batch or serial number, or product number or another element allowing their identification [at least one of]

Serial number
VLT-000102-R1
Product number
09506000134352
Place of manufactureAnnex VI Part A 3

Definition: The place of manufacture (geographical location of a battery manufacturing plant) [town, region, country/jurisdiction]

Town/city of manufacture
Leipzig
Region of manufacture
Saxony
Country of manufacture
Deutschland DEU
Date of manufacturingAnnex VI Part A 4

Definition: The date of manufacturing [month and year]

September 2026
Battery weightAnnex VI Part A 5

Definition: The weight [unit kg]

452,5 kg
Battery capacityAnnex VI Part A 6

Definition: The capacity [unit Ah]

230 Ah
Battery chemistryAnnex VI Part A 7

Definition: The chemistry [code list]

Li-ion NMC - Lithium ion NMC
Hazardous substances present in the battery, other than mercury, cadmium or leadAnnex VI Part A 8

Definition: The hazardous substances present in the battery, other than mercury, cadmium or lead [free text]

  • Lithium hexafluorophosphate (LiPF6)
  • Cobalt compounds
  • Nickel compounds
Usable extinguishing agentAnnex VI Part A 9

Definition: Usable extinguishing agent [free text]

Große Mengen Wasser zur Kühlung des Packs.
Critical raw materials present in the batteryAnnex VI Part A 10

Definition: Critical raw materials present in the battery in a concentration of more than 0,1 % weight by weight [code list]

Lithium Cobalt naturalGraphite
Renewable content shareAnnex XIII 1 (f)

Definition: The share of renewable content [%]

18%
Minimal voltageAnnex XIII 1 (h)

Definition: Minimal voltage, with temperature range when relevant [unit V, optional unit °C]

600 V at -20 … 55°C
Nominal voltageAnnex XIII 1 (h)

Definition: Nominal voltage, with temperature range when relevant [unit V, optional unit °C]

800 V at -20 … 55°C
Maximum voltageAnnex XIII 1 (h)

Definition: Maximum voltage, with temperature range when relevant [unit V, optional unit °C]

920 V at -20 … 55°C
Original power capabilityAnnex XIII 1 (i)

Definition: Original power capability [unit W]

300.000 W
Power limitAnnex XIII 1 (i)

Definition: Power limits, with temperature range when relevant [unit W, optionally min_T °C … max_T °C]

  • 300.000 W at 10 … 45°C
  • 120.000 W at -20 … 10°C
Temperature range the battery can withstand when not in useAnnex XIII 1 (l)

Definition: Temperature range the battery can withstand when not in use (reference test) [min_T °C … max_T °C + free text]

Value range
-20 … 45°C
Reference test for the temperature range the battery can withstand when not in use
IEC 62660-2 storage test; store between -20 °C and 45 °C at 30–50 % SoC en-IE
Period for which the commercial warranty for the calendar life appliesAnnex XIII 1 (m)

Definition: Period for which the commercial warranty for the calendar life applies [months]

96 Monate
Internal battery cell resistanceAnnex XIII 1 (o)

Definition: Internal battery cell resistance [unit Ω]

0,001 Ω
Internal battery pack resistanceAnnex XIII 1 (o)

Definition: Internal battery pack resistance [unit Ω]

0,11 Ω
Separate collection symbolAnnex XIII 1 (q)

Definition: The marking requirements laid down in Article 13(4) [Yes/No]

Ja
EU declaration of conformityAnnex XIII 1 (r)

Definition: The EU declaration of conformity referred to in Article 18 [a web link]

EU declaration of conformity PDF · en-GB
Waste battery prevention and management informationAnnex XIII 1 (s)

Definition: The information regarding the prevention and management of waste batteries laid down in Article 74(1), points (a) to (f) [multiple free text]

Impact of substances present in batteries on the environment and on human health or the safety of persons
Improper disposal may release electrolyte and heavy metals into soil and water. en-IE
Information on separate collection points
https://example.com/collection-points en-IE
Information on take-back and collection points
Return to any authorised dealer free of charge. en-IE
Meaning of the labels and symbols on batteries
The crossed-out wheelie bin symbol indicates separate collection is required. en-IE
Role of end-users in waste prevention
End users should avoid mechanical damage and follow the usage instructions. en-IE
Information on preparation for reuse facilities
Authorised facility: Iberia Reuse Centre, Zaragoza. en-IE
Safety instructions for handling waste batteries
Store damaged batteries in a dry, ventilated, non-flammable container. en-IE
Role of end-users in separate collection of waste batteries
End users must not dispose of batteries as unsorted municipal waste. en-IE
Information on treatment facilities for waste batteries
Authorised recycling plant: Recycla Ibérica, Bilbao. en-IE
Information on preparation-for-repurposing facilities
Authorised facility: Iberia Second-Life Hub, Valencia. en-IE
Expected battery lifetime in cyclesAnnex XIII 1 (j)

Definition: Expected battery lifetime expressed in cycles [in number]

2.500
Reference test used for expected battery lifetime expressed in cyclesAnnex XIII 1 (j)

Definition: Reference test used for expected battery lifetime expressed in cycles [free text]

IEC 62660-1 cycle life test at 25 °C, 1C/1C, 100 % DoD en-IE
Capacity threshold for exhaustionAnnex XIII 1 (k)

Definition: Capacity threshold for exhaustion [%]

70%
Initial round-trip energy efficiencyAnnex XIII 1 (n)

Definition: Initial round trip energy efficiency [%]

95,5%
Round-trip energy efficiency at 50% of cycle lifeAnnex XIII 1 (n)

Definition: Round trip energy efficiency at 50 % of cycle-life [%]

93%
Charge C-rate of relevant cycle-life testAnnex XIII 1 (p)

Definition: Charge C-rate of relevant cycle-life test [number]

1 h⁻¹

Restricted 1

Annex XIII (2)🔒 Eingeschränkt

Zugänglich für: Persons with legitimate interest, notified bodies, market surveillance authorities, Commission

4 Datenpunkte
  • Detailed composition
  • Part numbers for components and contact details of sources for replacement spares
  • Dismantling information
  • Safety measures

Restricted 2

Annex XIII (3)🔒 Eingeschränkt

Zugänglich für: Notified bodies, market surveillance authorities, Commission

1 Datenpunkte
  • Results of test reports proving compliance

Restricted 3

Annex XIII (4)🔒 Eingeschränkt

Zugänglich für: Persons with legitimate interest (individual battery)

17 Datenpunkte
  • Energy round trip efficiency
  • Energy round trip efficiency fade
  • Battery status
  • Number of charging cycles
  • Number of discharging cycles
  • Negative events
  • Periodically recorded information on the operating environmental conditions
  • Periodically recorded state of charge (SoC)
  • Rated capacity
  • Capacity fade
  • Power capability
  • Power fade
  • Internal resistance
  • Internal resistance increase
  • Expected lifetime of the battery under the reference conditions in cycles
  • Expected lifetime of the battery in years
  • State of certified energy (SOCE)

Mit Zugangsschlüssel entsperren

Zugang beantragen (berechtigtes Interesse)

Reparaturbetriebe, Recycler und Second-Life-Betreiber können beim Wirtschaftsakteur eingeschränkte Daten anfordern (Art. 77 Abs. 2 lit. a).

Datengruppen

Prüfung

  • Signatur gültig
    Aussteller: did:web:dpp.wisecraft.dev:orgs:voltaris
  • Nicht widerrufen
  • EU-DPP-Register: Noch nicht registriert
  • Sicherungskopie: backup://Independent replica volume (VPS /var/backups)/demo-voltaris/65d734ce-fdaa-49a1-aeb4-b7171e2d43f3/v1.json

Maschinenlesbar

Versionsverlauf

  1. Version 1 · 09.11.2026, 17:35 UTC
    issued
    Ausgestellt mit 61 Datenpunkten
    JSON